‹ Medium Voltage Switchgear
HXGW-12
Outdoor box-type switching station
12 kV · 630 A · 25 kA 4 s
HXGW-12 puts one or more SF6 load-break switches in a compact stainless-steel double-layer enclosure for outdoor sectionalising. Prefabricated silicone-rubber cable heads are fully sealed, fully insulated and maintenance-free, so local outages can be isolated without touching the main network.

Tested and certified
Designed to IEC 62271-200 / GB 3906
Built for
Distribution networks, Industrial estates, Solar and wind feeders.
Standards
IEC 62271-200, GB 3906.
Technical data
| Parameter | Value |
|---|---|
| Rated voltage / current | 12 kV / 630 A |
| Power-frequency withstand (to earth) | 42 kV |
| Lightning impulse | 75 kV |
| Rated breaking current | 630 A |
| Short-circuit making, peak | 50 kA |
| Short-time withstand | 25 kA / 4 s |
| Capacitive / inductive breaking | 45 A / 16 A |
| Full-load breaks / mechanical operations | > 100 / 2000 |
| Branch circuits | Up to 8, each optionally with switch; lightning arresters, fault indicators and current-limiting fuses optional |
| Enclosure | Stainless double-layer, service life > 20 years |
Standards
- IEC 62271-200
- GB 3906
Applications
- Distribution networks
- Industrial estates
- Solar and wind feeders
Production process
From enquiry to commissioning
- Enquiry and analysisSend a single-line diagram, load list or panel schedule. An engineer confirms voltage, short-circuit level, forms of separation and applicable standards within 24 hours.
- Proposal and drawingsBudgetary quotation in five working days, then general-arrangement drawings, busbar sizing and a bill of materials for approval.
- Order and engineeringApproved drawings release procurement of Schneider, ABB or specified components and sheet-metal programming.
- Fabrication and assemblyLaser cutting, CNC bending, powder coating, busbar processing, primary assembly and secondary wiring in Shaoshan.
- Factory acceptance testDielectric, loop-resistance, insulation, earth-continuity, IP and current-injection tests; customers and consultants welcome to witness.
- Delivery and after-salesExport packing, sea or air freight, commissioning support and a 7×24 service line with Schneider-trained engineers.
Also in medium voltage switchgear

Armoured withdrawable MV switchgear, 12 kV
The standard 12 kV metal-clad switchgear for incoming, feeder and coupler duty. Type-tested at 1250 A / 31.5 kA.
3.6 / 7.2 / 12 kV630–1250 A16–31.5 kA
Product detail

Armoured withdrawable MV switchgear, 40.5 kV
40.5 kV metal-clad switchgear accepting ZN85, HVX40, VD4, 3AE8 and CV2 breaker trucks. Main bus through without transition cabinets.
40.5 kV1250–2500 A31.5 kA
Product detail

Indoor SF6 ring main unit, 12 kV
Compact, metal-enclosed SF6 ring main unit with load-break switches and fuse-switch combinations for 12 kV ring and radial networks.
12 kV630 A20 kA 3 s
Product detail

MV automatic reactive-power compensation
6 kV and 10 kV capacitor banks with vacuum-contactor switching, per-group protection and RS485 control.
6 / 10 kVPF > 0.9RS232 / 485
Product detail
Quote this product
Send the single-line diagram, short-circuit level and panel schedule; a budgetary quotation follows within five working days.